Brand Name: Topband
Model Number: TB-027070180D-Fe-25Ah
Certification: UL1642, IEC61233
Place of Origin: China
MOQ: 4000pcs
Supply Ability: 450Mwh/year
Delivery Time: 2~4weeks for samples; 4~6weeks for mass production
Price: Negotiable
Packaging Details: standard export carton
Payment Terms: L/C, T/T
Type: LiFePO4( lithium iron phosphate)
Max charge: 1C
Max Discharge: 3C
Max pulse Discharge Current: 5C
Internal Impedance: ≤4mΩ
Capacity: 10AH / 12AH / 20AH / 25AH / 27AH / 50AH
Cycle life: ≥2000cycles @ 100% DOD
Calendar life: 8 years
Pole torsion: ≤5.5N•m
Warranty: 2 years
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Lifepo4 Battery Cells Low Self - Discharge 25ah cell

    Environment - Friendly LiFePO4 Battery Cells Low Self - Discharge Lithium Iron Phosphate


    · long life & deep cycle( over 2000cycles @ 100%DOD)

    · with built-in PCM/BMS protection

    · super quick charge/discharge performance

    · safe pressure valve design ( no explosion, no fire)

    · high energy density

    · low self-discharge( <3% per month,<15% per year)

    · 1/3 weight & 1/2 volume of lead acid battery

    · eco-friendly

    · high consistency

    · no memory effect

    · easily replace lead acid battery


    Lead acide battery VS. Topband LiFePO4 battery
    ItemLead acid batteryLiFePO4 batteryComparison results
    wh/kg30-45100-150LiFePO4 battery is 1/3 weight of lead acid battery
    wh/L60-80200-250LiFePO4 battery is 1/2 volume of lead acid battery
      conclusion 1LiFePO4 battery has higher energy density than that of lead acid battery.
    cycle life300-500cycles2000cycles @80% DOD
    1500cycles @100% DOD
    LiFePO4 battery's life cycle is 5times of that of lead acid battery, and more cycles at deep discharge
      conclusion 2LiFePO4 battery has much better cycle life.
    charge rate≤0.3C0.5-1CLiFePO4 battery can bare quick charge, eg., 2hs full charge for LiFePO4 battery, while more than 6hs for lead acid battery.
    discharge rate3-5C,only 30%-40% capacity release under 3C discharge3-10C, 80%-90% capacity release under 3C dischargeLiFePO4 battery support high rate discharge, and more capcity release under high rate discharge
      conclusion 3LiFePO4 battery has higher charge & discharge rate.
    self-discharge rate3-10%<1.5%lead acid battery will be useless for long time storage, LiFePO4 battery can stock for long time
      conclusion 4LiFePO4 battery has lower self-discharge rate.
    pollutionPb( against Rohs)N/A 
      conclusion 5LiFePO4 is more eco-friendly.
    maitenanceneed fill water constantlyfree maitenance 
      conclusion 6LiFePO4 need no maitenance.
    protectionNABMS 
      conclusion 7LiFePO4 has built in BMS for better control.
    optional feature bluetooth connectionTopband LiFePO4 allow users read battery info.
      conclusion 8Topband LiFePO4 support bluetooth connection.
    warranty12-18months24months 
      conclusion 9Topband LiFePO4 has longer warranty.
    pricehigher
    (unit price/300cycels)
    15%~25% lower than SLA battery(unit price/2000cycles) 
      conclusion 10LiFePO4 is more cost effective in long run.
    SummaryLiFePO4 battery meets the trend of development
     LiFePO4 battery is better than lead acid battery from different points of view.

    1. General

    This Product Specification describes the technique requirements, test procedures and precaution notes of prismatic type Lithium iron phosphate rechargeable cell, manufactured by SHEN ZHEN TOPBAND New Energy Technology CO.,LTD.

    2. Main product specification

    No.itemstandardremark
    2.1Nominal Capacity25Ah25±5℃,1C discharge
    2.2Internal Impedance≤4mΩ
    2.3Nominal Voltage3.2V
    2.4Cell Weight650±20g
    2.5End-of-charge Voltage3.65VAt CC mode
    2.6End-of-charge Current0.05CAt CV mode
    2.7End-of-discharge Voltage2.00V
    2.8Standard Charge Method1C CC/CV25±5℃
    2.9Max pulse Discharge Current5CContinuous Discharge Time: 10 seconds
    2.10Cycle Life≥2000cycles

    1C Continual Discharge: ≥80%

    (100% DOD)

    2.11Calendar life8years
    2.12Charging Temperature0~45℃
    2.13Discharging Temperature-20~55℃
    2.14Storage Temperature-10~30℃
    2.15

    Pole torsion


    ≤5.5N·mLock nut is recommended
    2.16AppearanceWithout break, scratch, distortion, contamination, leakage and so on

    3. Test Conditions

    3.1 Standard Test Conditions

    3.1.1 Unless specified otherwise, all tests stated in this Product Specification are conducted at temperature 25℃±5℃ and humidity 15%~75℅RH, and atmospheric pressure 86 kPa~106kPa.

    3.1.2 Unless specified otherwise, all the product characteristics are tested with the products less than one month from shipping date and unused.

    3.2 Standard Charge Method

    In ambient temperature of 25℃±5℃, 1C discharge the cell until the voltage drops to 2.0V, standby for one hour, then charge at a constant current of 1C until the voltage is 3.65V, then charge at a constant voltage of 3.65V until its current decreases to 0.05C, standby for one hour after charge.

    4. Electrical Characteristics

    item

    Criteria


    Test methodCharge & discharge curve

    4.1 High

    Temperature

    Discharge Performance


    Capacity retention at 55℃

    :≥95%

    A cell is charged in accordance with 3.2, and stored in high temperature chamber at 55℃for 5 h, then discharged to cut-off voltage at a constant current of 1C. After that, fetch out the cell and place it in the ambient temperature of 25℃±5℃ for 4 h, then check its appearance.

    4.2 Low

    Temperature

    Discharge

    Performance


    Capacity retention at -20℃

    :≥70%


    A cell is charged in accordance with 3.2, and stored in certain ambient temperature for 24hours,then discharged to cut-off voltage(1.8V) at a constant current of 1C. After that , fetch out the cell and place it in the ambient temperature of 25℃±5℃for 4hours.


    4.3

    Rate Charge Performance

    in Normal Temperature


    2C charge capacity≥80%


    Under the ambient temperature of 25℃±5℃,

    a, 1C constant discharge till the cut-off voltage, standby for 1h;

    b, charge at certain current till 3.65V, standby for 1h;

    c, constant discharge with 1C current till 2.0V.

    4.4

    Rate Discharge Performance in Normal Temperature


    3C discharge capacity≥95%


    A cell is charged in accordance with 3.2, then discharged to cut-off voltage at certain current in an ambient temperature of 25℃±5℃.


    4.5 Cycle Life

    (25℃±5℃)


    ≥2000cycles

    A cell is 1C CC/CV 3.65V fully charged, after that stored for 30min; Subsequently, the cell is discharged to cut-off voltage at a constant current of 1C, and stored 30min prior to next charge-discharge cycle, until the capacity retention<80%, and record all the cycles



    5. Environmental Characteristics

    No.Item

    Test Method


    Criteria


    5.1Temperature shock test

    A cell is charged in accordance with 3.2, and then repeat the following procedures for 5 cycles, then check the cell's appearance.

    No leakage, no fire, no explosion, no vent
    5.2

    Low-pressure

    Test


    A cell is charged in accordance with 3.2, then stored for 6h at a vacuum of -90KPa, after that put the cell in room temperature for 6h, then check the cell's appearance.


    No leakage, no fire, no explosion, no vent
    5.3Vibration Test

    A cell is charged in accordance with 3.2, and then installed onto the vibration desk with clamps. Equipment parameters of frequency and amplitude are set as bellow (the frequency is to be varied at the rate of 1oct/min between 10 and 55 Hz, and repeat vibration for 30 min. The cell is tested in three mutually perpendicular directions, i.e. X,Y,Z):

    (a) frequency:10Hz~30Hz, amplitude: 0.38mm;

    (b) frequency:30Hz~55Hz amplitude: 0.19mm

    1.No scratch, no fire, no explosion, no vent;

    2.The voltage is not less than 3.2V.

    5.4

    Shock Test


    A cell is tested in accordance with 3.2, and then secured to the testing machine by means of rigid mount which supports all mounting surfaces of the cell. Each cell shall be subjected to a total of three shocks of equal magnitude. The shocks are to be applied in each of three mutually perpendicular directions. The acceleration and impulse time are as follows: acceleration of impulse peak value:100m/s2, shock frequency:40~80 times/min,

    impulse lasting time:16 min,shock times:1000±10


    1.No scratch, no leakage, no fire, no explosion, no vent;

    2.the voltage is not less than 3.2V.


    6. Safety test

    All below tests are carried out on the equipment with forced ventilation and explosion-proof device. Before test, all cells are charged in accordance with 3.2, and stored 24h prior to test.


    No.Item

    Test Method


    Criteria


    6.1Short- circuit TestA cell is tested in accordance with 3.2, after that the cell is short-circuited by connecting the positive and negative terminals with a wire for 10min, the wire has a maximum resistance load of 5mΩ., then observe for 1h.No fire, no explosion
    6.2

    Overcharge

    Test


    A cell is tested in accordance with 3.2, then 1C constant current charged till the voltage reaches 1.5 times of the specified end-off charge voltage, or the charge time reaches 1h, then stop charge, and observe for 1h.

    No fire, no explosion


    6.3Over discharge testA cell is tested in accordance with 3.2, then 1C discharge for 90min, then observe for 1h.No fire, no explosion, no leakage
    6.4Crush TestA cell is tested in accordance with 3.2, and then is placed on the crush flat, the axis is parallel to the crush flat, and it is crushed between two flat surfaces till the crushing force is gradually approaching 200 kN, or voltage reaches 0V,or reaches 30% distortion, then observe for 1h.No fire, no explosion
    6.5

    Impact Test


    A cell is tested in accordance with 3.2, and then placed on the impact flat. A Φ15.8mm bar is to be placed on the center of the cell. A 9.1kg weight is dropped from a height of 610mm onto the cell, the distortion is allowed.No fire, no explosion
    6.6

    nail penetration Test


    a) A cell is tested in accordance with 3.2;

    b) use φ5mm~φ8mm high temperature resistance steel needle, with speed of 25±5mm/s, to go through the cell from vertical direction of pole plate, the penetrate position should be close to the geometric center of plate surface, the steel needle remains in the cell;

    c)observe for 1h.

    No fire, no explosion
    6.7

    Heating

    Test(130℃)

    A cell is tested in accordance with 3.2, and then heated in a circulating air oven. The temperature of the oven is raised at a rate of 5℃ per minute to 130℃±3℃ and remain for 30 min.No fire, no explosion
    7. Dimension
    Quality Lifepo4 Battery Cells Low Self - Discharge 25ah cell for sale
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Topband Battery Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 xpshou.com. All rights reserved.