Product name: 25 kW EKDB100A(R) high static pressure duct type air conditioning unit
Cooling capacity: 25 kW
Heating capacity: 29 kW
Air Flow: 5000 (m3/h)
Model: 1 indoor unit /1 outdoor unit
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Residential Unitary DX Split Air Conditioning Units 25 kW With Fully Hermetic Volute

25 kW EKDB100A(R) high static pressure duct type air conditioning unit


Specifications:


Unit modelIndoor unitEKDB100AEKDB100AREKDB100AEKDB100AR
Outdoor unitEKAA100ABEKAA100ARBEKAA100ABEKAA100ARB
Nominal cooling capacityW25000250002500025000
Nominal heating capacityW--29000--29000
Indoor unitAir flowm3/h50005000
External static pressurePa100150
Fan drive mode Three-speed motor driveV-belt transmission
Width x depth x heightmm1890x879x4201580x1020x520
Weightkg120150
Outdoor unitCompressor model Fully hermetic volute
Width x depth x heightmm990x840x1840 990x840x1840 
Weightkg265280265280
Power supply380V/3N~/50Hz   
Rated input power
of integrated unit
CoolingW109201096593309400
HeatingW--9750--9750
Rated current of integrated unitCoolingA23232122
HeatingA--22--22
RefrigerantType R22
Connection pipeConnect mode Soldering
External diameter of liquid tubemm15.8815.88
External diameter of air tubemm28.628.6
Condensed water drainage pipe R1
External electric heater boxModel ACDB-EH6, ACDB-EH8, ACDB-EH10, ACDB-EH12.5, ACDB-EH15, ACDB-EH20, ACDB-EH25, ACDB-EH30, ACDB-EH38, ACDB-EH45, ACDB-EH55
Description You can select an external electric heater box according
to the required heating capacity. For specifications of external electric heater boxes, see P22.

Description:


1. Outstanding Performance

Outstanding fans, motors and other components specially designed for air conditioners ensure that the unit operates smoothly.

Brand-new dustproof and rustproof painting makes sure that the outdoor unit looks new after many years of operation.


2. Easy Installation

Featuring a high static pressure design, the indoor unit can supply conditioned air over a long distance, enabling customers to select the installation site as required. To service any component of the unit, you only need to remove several screws on either side of the unit.

The connection pipe between indoor and outdoor units reaches up to 50 m, and the height difference can reach 20 m.

The outdoor unit adopts top air supply, allowing combined installation of multiple outdoor units for pleasant appearance.


3. Silent Operation

The indoor unit features an efficient and low-noise centrifugal fan as well as sound-absorbing and thermal insulation inner walls to ensure silent operation.

The indoor unit can be mounted on a far-away ceiling to make the conditioned room more silent.

Unique insulation design for compressors ensures an outstanding insulation performance.

The outdoor unit uses new spiral fans, which have smooth an air suction structure, greatly reduce turbulent flows, and lower the air flow noise.


4. Smart Control

The smart microcomputer controller supports four operation modes: cooling, heating, fan, and auto control. It also provides timed ON/OFF, auto-defrosting, and fault display functions.


5. Increasing Efficiency and Saving Energy

The unit uses a brand efficient volute compressor, which consumes less electricity while providing the same cooling/ heating capacity. The compressor features a small volume and stable running. The unit uses advanced thermal expansion valve control technology to accurately control tributary flows.


6. Power Recovery and Memory Functions

During operation, if the power fails, the unit can automatically start once the power resumes no matter how long the power failure lasts. After starting from an exceptional power failure, the unit automatically resumes the running status before the power failure. This function is not enabled upon factory delivery. It needs to be set through DIP switches on site.


7. Wide Application Scope

The unit has strong adaptability to the environment. It can normally perform cooling when the outdoor temperature is between 18°C and 48°C. It can normally perform heating when the outdoor temperature is between -10°C and 27°C.

The outdoor unit of the low-temperature cooling unit uses a brushless DC motor to control the rotation speed of the condensing fan, efficiently expanding the operating range of the unit and allowing it to normally perform cooling when the outdoor ambient temperature is between -10°C and 48°C.

Multiple types of units with electric heater boxes or hot water coil boxes are available.


8. Optimized System and Quiet Running

The outdoor unit produces a low noise. The system is optimized to suppress vibration and noise during operation, achieving quiet and stable unit running.

9. Wide Voltage Range

The unit normally runs within ±10% of the rated voltage


10. Multiple Protections

The unit provides high/low voltage protection, air exhaust temperature protection, overload protection, protection against phase loss or inversion, minimum downtime protection, minimum running time protection, and so on, minimizing damage to the unit. Faults are alarmed and displayed at the first moment, facilitating
troubleshooting. The unit provides phase loss/inversion protection. In the case that the power supply encounters phase loss or inversion, the protection device protects the running unit.Protection against phase inversion is designed for volute compressors.


11. Dual-sided spraying for long lifecycle

The shell of the outdoor unit is sprayed with anti-UV and pure polyester mineral highlighter on dual sides, effectively prolonging the lifecycle of the unit.


Competitive Advantage:


The EKDB high static pressure duct type air conditioning unit meets customer requirements for product efficiency, performance, safety, and intelligence. Flexible combination and intelligent control allow the product to fit into indoor space, bringing customers comfortable experience of a central air conditioner. In addition, a low temperature cooling unit is available. With its efficiency, low noise, delicate structure, easy operation, safe running, and convenient installation and maintenance, it is widely applicable to commercial scenarios such as hotels, malls, office buildings, and factory workshops.



Quality Residential Unitary DX Split Air Conditioning Units 25 kW With Fully Hermetic Volute for sale
Send your message to this supplier
 
*From:
*To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0